El tornillo de elevación da como resultado una corrección de inclinación sagital precisa en un modelo de fractura de radio distal.

Fuente
Este artículo es publicado originalmente en:

https://www.ncbi.nlm.nih.gov/pubmed/29559327

https://www.jhandsurg.org/article/S0363-5023(18)30221-1/fulltext

 
De:

Roebke AJ1Martin AS1Sarmast Z1Fisk E1Goyal KS2.

 2018 Jun;43(6):523-528. doi: 10.1016/j.jhsa.2018.02.011. Epub 2018 Mar 17.

 
Todos los derechos reservados para:

Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

 
 

Abstract

PURPOSE:

To determine the accuracy of a distal-first open reduction internal plate fixation technique in achieving correction of volar tilt in dorsally angulated distal radius fractures.
 

CONCLUSIONS:

Prereduction dorsal tilt can be accurately corrected within a few degrees of the goal by using the distal-first technique with an LOS. The LOS length can be calculated, and this technique can potentially be used with any distal radius periarticular locking plate with locking options in the shaft.

CLINICAL RELEVANCE:

A technique that provides accurate tilt correction would be of benefit to surgeons treating distal radius fractures with volar plates.

KEYWORDS:

Distal radius fracture; distal-first; dorsal tilt; sagittal tilt; volar tilt

 
 

Resumen

PROPÓSITO:

Determinar la precisión de una técnica de fijación de placa interna de reducción abierta de primer punto para lograr la corrección de la inclinación palmar en fracturas de radio distal con angulación dorsal.
 

CONCLUSIONES:

La inclinación dorsal previa a la reducción se puede corregir con precisión dentro de unos pocos grados de la meta al usar la técnica de primer punto distal con un tornillo de elevación (LOS). La longitud de LOS puede calcularse, y esta técnica puede usarse potencialmente con cualquier placa de bloqueo periarticular de radio distal con opciones de bloqueo en el eje.
 

RELEVANCIA CLÍNICA:

Una técnica que proporcione una corrección de inclinación precisa sería beneficiosa para los cirujanos que tratan fracturas del radio distal con placas volar.
 

PALABRAS CLAVE:

Fractura del radio distal; primero distal; inclinación dorsal; inclinación sagital; inclinación volar

 

Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

PMID:  29559327  DOI:  10.1016/j.jhsa.2018.02.011

 
 
 

Un método Sandwich utilizando fijación intrafocal Kapandji para facilitar la colocación de placas palmares para fracturas de radio distal desplazadas.

A Sandwich Method Using Kapandji Intrafocal Pinning to Facilitate Palmar Plating of Displaced Distal Radius Fractures.

 
Fuente
Este artículo es publicado originalmente en:
 

https://www.ncbi.nlm.nih.gov/pubmed/28671904

https://insights.ovid.com/crossref?an=00130911-201709000-00010

 
De:
 

Huang HK1, Huang YC, Wang JP, Chang MC.

2017 Sep;21(3):121-126. doi: 10.1097/BTH.0000000000000166.

 
Todos los derechos reservados para:
 

Copyright © 2017 Ovid Technologies, Inc., and its partners and affiliates. All Rights Reserved.
Some content from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.

 
 

Abstract

The use of palmar plating in the treatment of dorsally displaced distal radius fracture is very common, and can result in a good functional outcome. We present an easy «sandwich method» to reduce the fracture and to facilitate osteosynthesis. Firstly, the dorsal Kapandji intrafocal wire was applied to achieve the reduction of the dorsally displaced fracture and provide a volar-directed force. Then the intra-articular fractures were reduced or the metaphyseal defect is stuffed with bone graft if necessary. Finally, the anatomical plate is used to buttress and push back the distal fragment to complete the osteosynthesis. The postoperative radiographic parameters, comparing with the contralateral noninjured side, could achieve similar radial height, radial inclination, volar tilt, and ulnar variance without significant difference.

 
 

Resumen

 
El uso de placas palmar en el tratamiento de la fractura de radio distal desplazada dorsalmente es muy común y puede dar como resultado un buen resultado funcional. Presentamos un sencillo «método sándwich» para reducir la fractura y facilitar la osteosíntesis. En primer lugar, se aplicó el alambre dorsal Kapandji intrafocal para lograr la reducción de la fractura desplazada hacia la dorsal y proporcionar una fuerza dirigida a volar. Luego se redujeron las fracturas intraarticulares o se rellenó el defecto metafisario con injerto óseo si fuera necesario. Finalmente, la placa anatómica se usa para apoyar y empujar hacia atrás el fragmento distal para completar la osteosíntesis. Los parámetros radiográficos postoperatorios, en comparación con el lado no lesionado contralateral, podrían alcanzar una altura radial similar, inclinación radial, inclinación volar y varianza cubital sin diferencia significativa.
 

PMID:  28671904    DOI:  10.1097/BTH.0000000000000166